7309-BE-2RZP bearing: complete specifications & equivalents

The 7309-BE-2RZP is a ISO 15 radial bearing sized 45 x 100 x 25 mm (bore x OD x width) with RSR sealing. Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 100 mm d = 45 B = 25 mm side section front view
Principal dimensions: bore d 45 mm, outer diameter D 100 mm, width B 25 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand SKF
Bore diameter d 45 mm
Outer diameter D 100 mm
Width B 25 mm
Material GCr15
Seal / shield RSR
Internal clearance CN
Tolerance class P0
Cage polymer (PA66 glass-fibre reinforced)
Basic dynamic load rating C 55.9 kN
Basic static load rating C0 37.5 kN
Fatigue load limit Pu 1.6 kN
Reference speed (thermal) 8500 rpm
Limiting speed (mechanical) 6700 rpm
Operating temperature -40 to +120 °C
Mass 850 g
Manufacturer designation 7309 BE-2RZP
Standard ISO 15
Catalog version SKF PUB BU/P1 17000/1 EN (Oct 2018)
Last verified 2026-09-27

Source: catalog reference (SKF PUB BU/P1 17000/1 EN (Oct 2018)) · extracted 2026-09-27

Parameters extracted from the official SKF Rolling Bearings catalogue (SKF PUB BU/P1 17000/1 EN (Oct 2018)); SKF® and SKF Explorer® are trademarks of AB SKF, used here for identification only — mpnbase is not an authorized SKF distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at skf.com.

Dimensions in inches & 7300-series range

Bore d 1.772 in
Outer diameter D 3.937 in
Width B 0.984 in
ISO bore code 09
Radial section height (D−d)/2 27.5 mm
Smallest bore in 7300-series 10 mm
Largest outer diameter in 7300-series 420 mm
Width range across 7300-series 11–80 mm
Bore position in 7300-series (smallest first) 10 of 31
Bore above smallest 7300-series size 35 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
7309-BEP SKF full
Dimensions and internal design equivalent — standard interchange.
Same 45×100×25 mm envelope with catalogue ratings within 10 %; 7309 BEP is the glass-fibre PA66 cage, open arrangement execution of this size — boundary dimensions interchangeable, execution differs.
7309-BECBP SKF full
Dimensions and internal design equivalent — standard interchange.
Same 45×100×25 mm envelope with catalogue ratings within 10 %; 7309 BECBP is the glass-fibre PA66 cage, open arrangement execution of this size — boundary dimensions interchangeable, execution differs.
7309-BEGAPH SKF full
Dimensions and internal design equivalent — standard interchange.
Same 45×100×25 mm envelope with catalogue ratings within 10 %; 7309 BEGAPH is the PEEK cage, open arrangement execution of this size — boundary dimensions interchangeable, execution differs.
7309-BECBM SKF full
Dimensions and internal design equivalent — standard interchange.
Same 45×100×25 mm envelope with catalogue ratings within 10 %; 7309 BECBM is the brass cage, open arrangement execution of this size — boundary dimensions interchangeable, execution differs.
7309-BECBY SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 64/45 kN) — boundary dimensions match, not a load-rating equivalent.
7309-ACCBM SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 68/45.5 kN) — boundary dimensions match, not a load-rating equivalent.
QJ-309-N2MA SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 100/83 kN) — boundary dimensions match, not a load-rating equivalent.
QJ-309-MA SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 100/83 kN) — boundary dimensions match, not a load-rating equivalent.
QJ-309-N2PHAS SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 100/83 kN) — boundary dimensions match, not a load-rating equivalent.
QJ-309-PHAS SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 45×100×25 mm envelope, but catalogue C/C0 differ between executions (55.9/37.5 kN vs 100/83 kN) — boundary dimensions match, not a load-rating equivalent.
7309 SKF full
Dimensions and internal design equivalent — standard interchange.
SKF SKF 7309 BEP is the basic 45×100×25 mm angular-contact page with ratings within 10 % of this execution — same boundary dimensions, verify execution details.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the 7309-BE-2RZP model number is decoded

7309 BE-2RZP is SKF's 45 mm-bore single-row angular-contact ball bearing in the 7300 series, nominal 40° (B) contact angle, 45×100×25 mm to the ISO dimension plan. 40° contact angle (suffix B): the steep standard single-row angle, giving the highest axial capacity at the cost of speed, with a recommended load ratio Fa/Fr ≥ 1. E marks the optimized internal design with an enhanced ball complement and race geometry. glass-fibre reinforced PA66 cage, ball-centred (suffix P), with a 120 °C continuous-temperature ceiling. -2RZ marks non-contact NBR seals on both sides riding in recessed grooves: they keep contamination and the standard grease fill in without lip drag, and P again denotes the PA66 cage. Envelope 45×100×25 mm (1.772×3.937×0.984 in), 27.5 mm radial section height, C 55.9 kN, C0 37.5 kN, Pu 1.6 kN.reference speed 8,500 r/min (thermal) and limiting speed 6,700 r/min (mechanical), catalogue mass 850 g. Sizing arithmetic on the 45 mm bore: 55.9 kN C divided by the 27.5 mm radial section height gives 2.0 kN per section millimetre; the 850 g mass and 3 % Pu/C share frame the light-load floor for the adjusted-life check. The 1.6 kN fatigue load limit is the equivalent-load floor for long-life adjustment; with 55.9/37.5 kN ratings and 850 g mass this execution carries about 1.24 kN of C per millimetre of bore. Bore-to-OD planning: OD 100 over bore 45 is a 2.22× step for this size, and the 25 mm width gives a bore/width ratio of 1.80; use these ratios when housing space around the 45 mm shaft is the first constraint. Sealing note: the two non-contact NBR -2RZ seals run in recessed grooves without touching the inner ring, so drag and speed loss stay small while the standard grease fill is retained and coarse dust is excluded; they are not lip-contact seals, so pressure washing and fine slurry still require external housing seals. The uncapped BECBP/BEP executions are the open counterparts.

Typical equipment & failure modes

Common applications

  • gear pumps and screw-type pumps
  • centrifugal and vacuum pumps
  • industrial transmissions

Known failure patterns

  • ball skidding when the induced axial load unloads the inactive bearing of a pair
  • preload loss as a loosely clamped set runs slack and the balls smear the raceways
  • raceway smearing under minimum-axial-load starvation at light load and high speed
  • grease ageing inside the non-contact-sealed cavity after long service with no relubrication access
  • fretting corrosion on a loose rotating shaft seat
  • electrical pitting on VFD-driven shafts without grounding protection

Selection pitfalls — read before you substitute

  • DB pairs give the highest moment stiffness, DF pairs tolerate misalignment and thermal expansion better, DT shares heavy one-direction thrust; choose from the shaft thermal calculation rather than by habit.
  • Reference and limiting speeds are different ceilings: design to both, and remember preload and oil/air cooling move the real thermal limit far from the catalogue reference value.
  • Reference and limiting speeds are different ceilings: design to both, and remember preload and oil/air cooling move the real thermal limit far from the catalogue reference value.
  • Preload the set against a calculated stand-off dimension — the ground faces of BE-2RZP establish it, but locknut torque, sleeve crush and housing-face squareness each consume part of the allowance.
  • The steep 40° angle of 7309-BE-2RZP favours thrust-heavy combined loads; for a predominantly radial high-speed position the 25° ACCBM execution of the same size is the alternative order number.
  • The non-contact -2RZ seals of 7309-BE-2RZP add little drag but are not contact seals; in wet or fine-dust duty retain external sealing at the housing.

Frequently asked questions

What are the dimensions and catalogue data of 7309-BE-2RZP?

7309 BE-2RZP measures 45 mm bore × 100 mm OD × 25 mm width (1.772 × 3.937 × 0.984 in), mass about 850 g. SKF 17000 ratings: C 55.9 kN, C0 37.5 kN, Pu 1.6 kN, reference speed 8,500 r/min (thermal) and limiting speed 6,700 r/min (mechanical).

What does the BE-2RZP suffix mean?

40° contact angle (suffix B): the steep standard single-row angle, giving the highest axial capacity at the cost of speed, with a recommended load ratio Fa/Fr ≥ 1. E marks the optimized internal design with an enhanced ball complement and race geometry. glass-fibre reinforced PA66 cage, ball-centred (suffix P), with a 120 °C continuous-temperature ceiling. -2RZ marks non-contact NBR seals on both sides riding in recessed grooves: they keep contamination and the standard grease fill in without lip drag, and P again denotes the PA66 cage.

Can one 7309-BE-2RZP take thrust in both directions?

No. A single-row angular-contact bearing reacts axial load in one direction; reversing thrust needs a DB/DF matched pair (use a universally matchable CB/GA execution) or a double-row bearing. Under radial load the 40° angle induces an axial force that the arrangement must balance.

What minimum axial load does 7309-BE-2RZP need?

The balls must remain seated: SKF gives Fam ≈ A·(n·dm/1000)² and a load-ratio guideline of Fa/Fr ≥ 1 for the 40° B execution and ≥ 0,55 for the 25° AC execution. Preloaded pairs and spring loading are the usual ways of meeting it at light load and high speed.

Reviewed & verified by the MPN Base engineering desk against source catalog SKF PUB BU/P1 17000/1 EN (Oct 2018) on 2026-09-27. Read our editorial & correction policy.