BMO-6204-048S2-UA108A sensor bearing unit: specifications & signal data

The BMO-6204-048S2-UA108A is a sensor bearing unit sized 20 x 47 x 14 mm, rated 48 pulses per revolution with a 10000 rpm limiting speed per ISO 15. Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 47 mm d = 20 B = 14 mm side section front view
Principal dimensions: bore d 20 mm, outer diameter D 47 mm, width B 14 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand SKF
Bore diameter d 20 mm
Outer diameter D 47 mm
Width B 14 mm
Material GCr15
Cage steel, stamped ribbon (J-type)
Basic dynamic load rating C 12.7 kN
Basic static load rating C0 6.55 kN
Fatigue load limit Pu 0.28 kN
Limiting speed (mechanical) 10000 rpm
Mass 140 g
Manufacturer designation BMO-6204/048S2/UA108A
Standard ISO 15
Catalog version SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 17 sensor bearing units
Last verified 2026-10-19
Number of pulses per revolution N 48
Period accuracy 3 %
Phase shift between signals 90 °
Phase shift tolerance 20 °
Cable length 560 mm
Cable connector AMP Superseal plug
Electrical angle per pulse (360°/N) 7.5 °
Two-channel edges per revolution (4×N) 192
Pulses per shaft degree (N/360) 0.133
Output frequency at limiting speed (N×rpm/60) 8000 Hz
Signal period at limiting speed 0.125 ms
Output frequency at 1 000 r/min (N×1000/60) 800 Hz
Signal period at 1 000 r/min 1.25 ms
Output channels (two-signal) 2
Phase shift tolerance window 70 to 110 °

Source: catalog reference (SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 17 sensor bearing units) · extracted 2026-10-19

Parameters extracted from the official SKF Rolling Bearings catalogue (SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 17 sensor bearing units); SKF® and SKF Explorer® are trademarks of AB SKF, used here for identification only — mpnbase is not an authorized SKF distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at skf.com.

Dimensions in inches & BMO-series range

Bore d0.787 in
Outer diameter D1.85 in
Width B0.551 in
ISO bore code—
Radial section height (D−d)/213.5 mm
Smallest bore in BMO-series20 mm
Largest outer diameter in BMO-series52 mm
Width range across BMO-series14–15 mm
Bore position in BMO-series (smallest first)1 of 2
Bore above smallest BMO-series size0 mm

Cross references & equivalents

No verified interchange data yet. Send an inquiry and our team will confirm equivalents manually.

How the BMO-6204-048S2-UA108A model number is decoded

The 20 mm bore and 47 mm outside diameter carry the deep groove ball raceway while the 14 mm width houses the sensor ring; the published ratings are C 12.7 kN, C0 6.55 kN and a fatigue load limit Pu 0.28 kN. The encoder delivers 48 pulses per revolution as two output channels 90° apart, each pulse period accurate to ±3% and the phase held to within ±20°; limiting speed 10000 r/min. Because the sensor ring does not alter the ball raceway, the static-to-dynamic ratio stays at 1.939 (6.55 kN against 12.7 kN), matching the plain bearing of this size. Physically the unit is a 20/47/14 mm, 140 g assembly with a 560 mm cable ending in a AMP Superseal connector; the 48-pulse electronics are otherwise fixed for the size. At the 10000 r/min limiting speed the 48-pulse track produces 8000 Hz per channel, i.e. 7.5° of shaft rotation per output pulse; check the receiving controller's input frequency range against that figure. with a 20 mm bore this is a small sensor bearing unit; the 47 mm outside diameter keeps the housing bore within ordinary machined tolerances BMO-6206/064S2 style designations are decoded as bearing code, pulse block and interface block — the /064 is not a part number but the number of pulses per revolution, and S2 confirms two output channels. The trailing 108A marks the AMP Superseal connector variant, the plug-and-play interface used where a sealed automotive connector is required; the cable is 5 mm longer than the free-end version of the same size. The U/A block means a stamped steel ball cage, standard for the sizes where the higher load ratings rule out a polymer cage. typical applications include industrial automation axis control, conveyor pulley speed and direction sensing and pump and fan rotor speed feedback this unit is commonly specified for industrial automation axis control and conveyor pulley speed and direction sensing, where rotor position and speed sensing with a 48-pulse signal fits the controller's input in pump and fan rotor speed feedback the integrated bearing carries the shaft load while the sensor ring supplies the signal; the 140 g mass keeps the rotating inertia low the two output channels must be screened as a pair; running them alongside motor power cables induces noise that the controller can read as extra pulses the interface is not a resolver or a standard encoder protocol — the controller must accept the specific N-pulse two-signal format this unit produces mounting the unit on a rotor with excessive unbalance or axial play loads the sensor ring unevenly and shows up as a periodic error in the signal

Typical equipment & failure modes

Common applications

  • steer-by-wire hand-wheel input
  • industrial automation axis control
  • agricultural machinery rotor position sensing
  • servo motor rotor feedback

Known failure patterns

  • mounting the unit on a rotor with excessive unbalance or axial play loads the sensor ring unevenly and shows up as a periodic error in the signal
  • the two output channels must be screened as a pair; running them alongside motor power cables induces noise that the controller can read as extra pulses
  • the interface is not a resolver or a standard encoder protocol — the controller must accept the specific N-pulse two-signal format this unit produces
  • the embedded bearing shares its grease charge with the sensor assembly, so both the lubricant specification and the temperature range must be respected together
  • period accuracy is quoted as a percentage of one pulse period — the absolute angular error grows as the pulse count falls, so compare units at equal N

Selection pitfalls — read before you substitute

  • the two output channels must be screened as a pair; running them alongside motor power cables induces noise that the controller can read as extra pulses
  • the interface is not a resolver or a standard encoder protocol — the controller must accept the specific N-pulse two-signal format this unit produces
  • mounting the unit on a rotor with excessive unbalance or axial play loads the sensor ring unevenly and shows up as a periodic error in the signal

Frequently asked questions

What does the BMO prefix stand for?

BMO identifies a motor encoder unit that mounts directly on the rotor. The full designation BMO-6204/048S2/UA108A carries the pulse count, the two-signal configuration, the sales region, the cage material and the electrical interface, so the complete specification follows from the code.

What is the resolution of the BMO-6204-048S2-UA108A?

The unit outputs 48 pulses per revolution as two phase-shifted signals, with a period accuracy of ±3% and a nominal phase shift of 90° within ±20°.

Which bearing is inside the BMO-6204-048S2-UA108A?

The unit is built on a 6204 deep groove ball bearing of the 20/47/14 mm envelope, so the shaft and housing fits are the ordinary ISO 15 ones for that bearing size.

What connector does the BMO-6204-048S2-UA108A use?

The unit is supplied with an AMP Superseal connector and a 560 mm cable, outputting two 48-pulse signals. Fix the connector and cable variant at order time — the alternatives are not field-interchangeable.

Reviewed & verified by the MPN Base engineering desk against source catalog SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 17 sensor bearing units on 2026-10-19. Read our editorial & correction policy.