YET-211 bearing: complete specifications & equivalents

The YET-211 is a ISO 15 radial bearing sized 55 x 100 x 32.6 mm (bore x OD x width). Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 100 mm d = 55 B = 32.6 mm side section front view
Principal dimensions: bore d 55 mm, outer diameter D 100 mm, width B 32.6 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand SKF
Bore diameter d 55 mm
Outer diameter D 100 mm
Width B 32.6 mm
Material GCr15
Seal / shield open
Internal clearance CN
Tolerance class P0
Cage steel, stamped ribbon (J-type)
Basic dynamic load rating C 43.6 kN
Basic static load rating C0 29 kN
Fatigue load limit Pu 1.25 kN
Limiting speed (mechanical) 3600 rpm
Operating temperature -40 to +120 °C
Mass 1050 g
Manufacturer designation YET 211
Standard ISO 15
Catalog version SKF PUB BU/P1 17000/1 EN (Oct 2018)
Last verified 2026-09-28

Source: catalog reference (SKF PUB BU/P1 17000/1 EN (Oct 2018)) · extracted 2026-09-28

Parameters extracted from the official SKF Rolling Bearings catalogue (SKF PUB BU/P1 17000/1 EN (Oct 2018)); SKF® and SKF Explorer® are trademarks of AB SKF, used here for identification only — mpnbase is not an authorized SKF distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at skf.com.

Dimensions in inches & YEL2-series range

Bore d 2.165 in
Outer diameter D 3.937 in
Width B 1.283 in
ISO bore code —
Radial section height (D−d)/2 22.5 mm
Smallest bore in YEL2-series 12.7 mm
Largest outer diameter in YEL2-series 110 mm
Width range across YEL2-series 19.1–61.9 mm
Bore position in YEL2-series (smallest first) 24 of 27
Bore above smallest YEL2-series size 42.3 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
YET ISO 15 full
Dimensions and internal design equivalent — standard interchange.
ISO 15 boundary-dimension envelope; brand-specific OEM equivalents (NSK/FAG/NTN) pending multi-source data.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the YET-211 model number is decoded

Listed in SKF 17000 chapter 2, YET 211 is a eccentric-locking-collar insert bearing with a one-side-extended inner ring, 55x100x32.6 mm overall, whose convex spherical outer ring pivots in the spherical bore of a Y-pillow, Y-flange or take-up housing. Construction pairs capped deep-groove geometry with a one-piece eccentric locking collar and a convex outer ring — quick to mount on plain commercial shafts and tolerant of initial static misalignment. reading YET: an eccentric locking collar does the shaft clamping (popular where shaft tolerance and quick removal matter), inner ring extended on one side. the size code 211 carries the usual bore arithmetic — 55 mm (code 11 x 5) — while the leading 2 marks the ISO 15 diameter series 2 sphered-OD envelope. the bare designation means no factory seal package: unlike the -2F executions this bearing relies on enclosure by the Y-housing and its own re-greasing path, which is why it is normally specified inside well-sealed plummer and flange units. Envelope 55x100x32.6 mm (2.165x3.937x1.283 in), outer ring 25 mm wide, C 43.6 kN, C0 29 kN, Pu 1.25 kN. Mounted width B1 48.4 mm includes the eccentric collar. The catalogue publishes a single speed ceiling, the limiting speed: 3,600 r/min; mass 1050 g. Capacity density: 43.6 kN from 1.050 kg of bearing steel is about 41.524 kN per kilogram, and per width millimetre the 32.6 mm unit carries 1.337 kN of dynamic capacity. Spherical-seat note in numbers: the 100 mm OD is ground spherical, so the self-aligning pivot happens on a circle roughly pi x 77.5 = 243.473 mm in mean circumference — keep that interface greased, because corrosion locking turns the pivot into a fixed misaligned mount. Load balance for documentation: C0 29 kN against C 43.6 kN gives a 0.665 ratio; mounted-unit positions with shock and standstill loading are normally checked on C0, while conveyor and fan duty are evaluated on the L10 figure. Static-first planning: the 0.89 kN of C0 per overall-width millimetre is the figure for belt tension peaks and rotor imbalance standstill loads on the 55 mm shaft, not the 43.6 kN L10 value. Grease-life arithmetic is dominated by speed: at dn approx 2.79x10^5 the sealed-for-life fill is planned for the catalogue's grease-life regime, which is why the limiting speed and the relubrication interval move together, and high-temperature mounts shorten both even when load is light. One-side collar note: the eccentric collar mounts on the extended side only and must turn in the shaft rotation direction to self-tighten; on reversing drives this design can loosen by design intent — choose grub-screw or ConCentra locking for true bidirectional shafts. Direction rule for YET-211: the eccentric collar self-tightens in the shaft's running direction, so mark rotation at mounting; the 55 mm shaft must be free of burrs under the collar or the eccentric cannot bed flat.

Typical equipment & failure modes

Common applications

  • one-direction conveyor drives
  • agricultural machinery PTO-driven shafts
  • ventilation equipment with frequent bearing changes

Known failure patterns

  • eccentric collar mounted against rotation direction works loose and spins, fretting the shaft
  • collar forced on a reversing application repeatedly loads and unloads the eccentric, fretting both parts
  • pressure-greasing through the housing fitting at excessive pressure balloons the NBR seals out of their grooves
  • water or slurry past the seal lip emulsifies the life-long grease and rusts the flinger recess
  • sphered OD and spherical housing bore left dry or painted over: the static self-aligning feature freezes solid with corrosion

Selection pitfalls — read before you substitute

  • The eccentric collar is handed to running direction; fit it wrong on the 55 mm shaft and self-tightening becomes self-loosening. Mark the shaft rotation before stripping any YEL2 collar unit.
  • Overall width 48.4 mm includes collar space — a housing sized for a grub-screw insert of the same OD can be too narrow axially for the YET collar.
  • Never pin or weld the eccentric collar: the controlled eccentric friction is the locking principle, and pinning turns a demountable insert into a shaft-replacement job.
  • Catalogue ratings belong to YET 211 as the ecc one open execution; other order numbers of the YET 211 size are different articles (open vs sealed, plain vs rubberized flinger, stainless vs carbon steel) and may carry different ratings or speeds — always quote the full designation.

Frequently asked questions

What are the dimensions and catalogue data of YET-211?

The catalogue envelope is 55x100x32.6 mm with a spherical outside surface; mass 1050 g. Ratings C 43.6/29 kN, Pu 1.25 kN, limiting speed 3,600 r/min.

What does the designation YET 211 mean?

reading YET: an eccentric locking collar does the shaft clamping (popular where shaft tolerance and quick removal matter), inner ring extended on one side. the size code 211 carries the usual bore arithmetic — 55 mm (code 11 x 5) — while the leading 2 marks the ISO 15 diameter series 2 sphered-OD envelope. the bare designation means no factory seal package: unlike the -2F executions this bearing relies on enclosure by the Y-housing and its own re-greasing path, which is why it is normally specified inside well-sealed plummer and flange units.

What is the difference between YET and YEL?

YET has the inner ring extended on one side; YEL extends it on both sides. Both lock with the eccentric collar and share bore/OD geometry; the sealed -2F executions sit in the YEL listings.

Can eccentric-collar bearings run in both directions?

They are intended for one predominant running direction; true reversing drives can unwind the eccentric. For bidirectional or vibrating shafts choose grub-screw or SKF ConCentra (YSP) locking.

Reviewed & verified by the MPN Base engineering desk against source catalog SKF PUB BU/P1 17000/1 EN (Oct 2018) on 2026-09-28. Read our editorial & correction policy.