UCFL206 bearing: complete specifications & equivalents

The UCFL206 is a JIS B 1559 radial bearing sized 30 x 62 x 38.1 mm (bore x OD x width) with 2RS sealing. Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 62 mm d = 30 B = 38.1 mm side section front view
Principal dimensions: bore d 30 mm, outer diameter D 62 mm, width B 38.1 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand NTN
Bore diameter d 30 mm
Outer diameter D 62 mm
Width B 38.1 mm
Seal / shield 2RS
Basic dynamic load rating C 21.6 kN
Basic static load rating C0 11.3 kN
Fatigue load limit Pu 0.795 kN
Mass 800 g
Housing height H 148 mm
Housing overall length L 80 mm
Mounting bolt center distance J 117 mm
Mounting hole diameter N 16 mm
Manufacturer designation UCFL206
Standard JIS B 1559
Catalog version CAT. No. 2203-3/E 2024
Last verified 2026-09-25

Source: catalog reference (CAT. No. 2203-3/E 2024) · extracted 2026-09-25

Parameters extracted from the official NTN Ball and Roller Bearings catalogue (CAT. No. 2203-3/E 2024); NTN® is a trademark of NTN Corporation, used here for identification only — mpnbase is not an authorized NTN distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at ntnglobal.com.

Dimensions in inches & UCFL-series range

Bore d 1.181 in
Outer diameter D 2.441 in
Width B 1.5 in
ISO bore code 06
Radial section height (D−d)/2 16 mm
Smallest bore in UCFL-series 12 mm
Largest outer diameter in UCFL-series 300 mm
Width range across UCFL-series 31–145 mm
Bore position in UCFL-series (smallest first) 6 of 25
Bore above smallest UCFL-series size 18 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
UCFL206 ISO 15 verify
Commonly quoted cross reference; confirm against the target catalog before ordering.
ISO 15 boundary-dimension envelope; seal suffix convention varies by brand (2RS / DDU / LLU / 2RSR) — verify seal design and temperature range. Brand-specific OEM equivalents pending multi-source data.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the UCFL206 model number is decoded

For a 30 mm shaft ending at or passing through a vertical frame face, NTN UCFL206 is the diamond-flange answer: UC206D1 insert inside the FL206 cast-iron housing. The UCFL206 number follows NTN's mounted-unit convention: housing letter FL, 2-series section, bore code for 30 mm; FL206 and UC206D1 are the separate housing and insert part numbers inside. Shaft size is 30 mm; the 148 mm overall-height flange is 80 mm long across the rhombus (L), with its two mounting holes on 117 mm centres (J) clearing 16 mm M14 bolts. The 2-series section is the standard-duty choice — the slimmest, lightest housing at this bore, selected when shaft speed and load are moderate and space is normal. The diamond flange carries the shaft square to a vertical face — a welded frame, side plate or gearbox wall — so no base plinth and no shim pack under the bearing are required. This mid bore range dominates agricultural and bulk-handling builds, where standard shafts, cast feet and greasable inserts keep replacement a stock-room, not a workshop, exercise. HVAC air-handling units carry fan shafts on this size, usually in warm roof-space air where the grease must be rated for continuous ambient temperature rather than load. On V-belt drives, align the pulleys before finally tightening the feet; the spherical seat lets you rotate the unit, but sliding the whole base on the foundation is what removes the belt-edge wear. Basic ratings of the UC206D1 insert are 21.6 kN dynamic and 11.3 kN static; the assembled UCFL206 weighs about 0.8 kg.

Typical equipment & failure modes

Common applications

  • machine-tool chip conveyors
  • belt conveyor head, tail and bend pulleys
  • industrial fans and blowers
  • frequent stop-start and reversing duty such as shuttle and tripper conveyors

Known failure patterns

  • insert brinelling from hammer mounting or from belt tension applied to a stationary unit
  • over-greasing that churns the charge, overheats the bearing and blows the seal lip
  • cracked cast ear from mounting on an uneven face and pulling one bolt fully first

Selection pitfalls — read before you substitute

  • Never weld a bracket to the FL206 housing of UCFL206: local heat cracks cast iron and distorts the spherical bore that the insert depends on.
  • The standard section of UCFL206 can look adequate at 30 mm while the X or 3 section is the real choice for long conveyor centres; compare ratings rather than fitting the same unit line-wide.
  • The standard 2-series insert in UCFL206 is the lightest section at 30 mm — do not substitute it into a position that previously ran an X or 3 unit: the 117 mm mounting may match while the load rating does not.
  • As a rhombus flange, UCFL206 pulls against the frame through only two M14 bolts on 117 mm centres; the mounting plate must be stiff enough not to bend between them under belt load.
  • The lip seals and slingers on UCFL206 suit ordinary industrial dust; submerged or heavy slurry service needs a different sealed arrangement regardless of the load rating.

Frequently asked questions

When should I choose a rhombus flange unit like UCFL206 instead of a pillow block?

Choose the UCFL206 two-bolt flange when the 30 mm shaft meets a vertical frame or side plate: the diamond housing bolts flush with two M14 bolts on 117 mm centres. A UCP pillow block is used when the shaft runs above a horizontal mounting surface.

What loads can the UCFL206 unit carry?

The UC206D1 insert is rated at 21.6 kN dynamic and 11.3 kN basic static (fatigue load limit 0.795 kN). Mounted units are predominantly selected on radial load from belt pull and overhung weight; axial capacity is limited and should be checked separately.

What are the dimensions of an UCFL206 mounted bearing?

UCFL206 takes a 30 mm shaft (insert UC206D1, 62 mm OD) and has a unit mass of about 0.8 kg. Flange figures: height H 148 mm, length L 80 mm, bolt centres J 117 mm, holes 16 mm for M14 bolts.

What does the UCFL206 designation mean?

UC identifies the wide-inner-ring, setscrew-locking ball bearing insert; FL the two-bolt rhombus flange housing; 2 is the duty series; the last digits encode the 30 mm bore. UCFL206 is built from housing FL206 plus insert UC206D1 (D1 = greasable).

How is UCFL206 locked to the shaft, and how tight should the setscrews be?

The UC206D1 insert uses two collar setscrews on the 30 mm shaft. Tighten them to NTN's torque table for this bore size in sequence — half torque on the first, full on the second, then back to the first — and re-torque after the first 24–48 running hours once the collar has seated.

Reviewed & verified by the MPN Base engineering desk against source catalog CAT. No. 2203-3/E 2024 on 2026-09-25. Read our editorial & correction policy.