UCFL312 bearing: complete specifications & equivalents
The UCFL312 is a JIS B 1559 radial bearing sized 60 x 130 x 71 mm (bore x OD x width) with 2RS sealing. Verify dimensions against the official catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Brand | NTN |
| Bore diameter d | 60 mm |
| Outer diameter D | 130 mm |
| Width B | 71 mm |
| Seal / shield | 2RS |
| Basic dynamic load rating C | 90.5 kN |
| Basic static load rating C0 | 52 kN |
| Fatigue load limit Pu | 4.1 kN |
| Mass | 5700 g |
| Housing height H | 270 mm |
| Housing overall length L | 160 mm |
| Mounting bolt center distance J | 212 mm |
| Mounting hole diameter N | 31 mm |
| Manufacturer designation | UCFL312 |
| Standard | JIS B 1559 |
| Catalog version | CAT. No. 2203-3/E 2024 |
| Last verified | 2026-09-25 |
Source: catalog reference (CAT. No. 2203-3/E 2024) · extracted 2026-09-25
Parameters extracted from the official NTN Ball and Roller Bearings catalogue (CAT. No. 2203-3/E 2024); NTN® is a trademark of NTN Corporation, used here for identification only — mpnbase is not an authorized NTN distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at ntnglobal.com.
Dimensions in inches & UCFL-series range
| Bore d | 2.362 in |
|---|---|
| Outer diameter D | 5.118 in |
| Width B | 2.795 in |
| ISO bore code | 12 |
| Radial section height (D−d)/2 | 35 mm |
| Smallest bore in UCFL-series | 12 mm |
| Largest outer diameter in UCFL-series | 300 mm |
| Width range across UCFL-series | 31–145 mm |
| Bore position in UCFL-series (smallest first) | 12 of 25 |
| Bore above smallest UCFL-series size | 48 mm |
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| UCFL312 | ISO 15 | verify Commonly quoted cross reference; confirm against the target catalog before ordering. | ISO 15 boundary-dimension envelope; seal suffix convention varies by brand (2RS / DDU / LLU / 2RSR) — verify seal design and temperature range. Brand-specific OEM equivalents pending multi-source data. |
Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the UCFL312 model number is decoded
NTN delivers UCFL312 as a matched unit — the UC312D1 insert is locked into the FL312 rhombus cast-iron flange at the factory and arrives greased and sealed. NTN's numbering ties the unit to its components: UCFL312 means the FL312 housing carrying the UC312D1 insert, with the last two digits denoting the 60 mm bore in the 3-series duty class. The mounting detail needs four numbers: H 270 mm flange height, L 160 mm across the ears, J 212 mm between the 31 mm holes, and a 60 mm shaft through the 130 mm OD UC312D1 insert. The 3-series section is the heavy-duty end of the range: a UC3 high-capacity insert in the longest, strongest housing, specified for shock loads and long conveyor centres. The diamond flange carries the shaft square to a vertical face — a welded frame, side plate or gearbox wall — so no base plinth and no shim pack under the bearing are required. At 55–90 mm bore the units carry serious conveyor, fan and crusher-feed drives; housing stiffness, foundation condition and bolt torque matter as much as the insert rating. Crane and hoist travel drives occasionally use this unit when the shaft runs parallel to the rail: the pillow base bolts to a machined trolley plate and survives repeated travel shocks. When a shaft journal is scored under the setscrew points, do not rotate the insert to a fresh spot on the same shaft — sleeve the journal or move the unit, or the indentations let the ring creep again. Basic ratings of the UC312D1 insert are 90.5 kN dynamic and 52 kN static; the assembled UCFL312 weighs about 5.7 kg.
Typical equipment & failure modes
Common applications
- sawmill arbors and feed rolls
- cement and clinker handling
- sugar-mill and fertiliser plant drives
- washdown-duty food and pharmaceutical areas using purge relubrication
Known failure patterns
- lip-seal failure from grit past the slinger, followed by grease loss and abrasive wear
- spherical-seat fretting that welds insert to housing and destroys the self-aligning action
- water-emulsified grease after washdown with the fitting facing upward
Selection pitfalls — read before you substitute
- As a rhombus flange, UCFL312 pulls against the frame through only two M27 bolts on 212 mm centres; the mounting plate must be stiff enough not to bend between them under belt load.
- At replacement time, measure the 60 mm shaft journal — a worn or deeply indented journal under the setscrews will let a brand-new UCFL312 creep identically to the old one.
- UCFL312 is located on the shaft by setscrews only; for shock reversing drives consider an adapter-lock insert family instead, since setscrew points indent the 60 mm journal over time.
- At 60 mm bore the 160 mm base of UCFL312 is a structural member: grout or machine the foundation, because a bedded-on-edges housing concentrates the full belt pull on two cast feet.
- The 3-series insert makes UCFL312 the highest-rated unit at 60 mm; its advantage disappears on a soft foundation, so spend the saved margin on base stiffness rather than skipping shims.
Frequently asked questions
What does the UCFL312 designation mean?
UC identifies the wide-inner-ring, setscrew-locking ball bearing insert; FL the two-bolt rhombus flange housing; 3 is the duty series; the last digits encode the 60 mm bore. UCFL312 is built from housing FL312 plus insert UC312D1 (D1 = greasable).
How is UCFL312 locked to the shaft, and how tight should the setscrews be?
The UC312D1 insert uses two collar setscrews on the 60 mm shaft. Tighten them to NTN's torque table for this bore size in sequence — half torque on the first, full on the second, then back to the first — and re-torque after the first 24–48 running hours once the collar has seated.
When should I choose a rhombus flange unit like UCFL312 instead of a pillow block?
Choose the UCFL312 two-bolt flange when the 60 mm shaft meets a vertical frame or side plate: the diamond housing bolts flush with two M27 bolts on 212 mm centres. A UCP pillow block is used when the shaft runs above a horizontal mounting surface.
Is the UCFL312 bearing self-aligning?
Yes within limits. The UC312D1 insert has a spherical outer diameter that pivots in the FL312 housing bore, compensating for a few degrees of static misalignment between shaft and foundation. It does not compensate for a bent shaft or dynamic deflection while running.
What are the dimensions of an UCFL312 mounted bearing?
UCFL312 takes a 60 mm shaft (insert UC312D1, 130 mm OD) and has a unit mass of about 5.7 kg. Flange figures: height H 270 mm, length L 160 mm, bolt centres J 212 mm, holes 31 mm for M27 bolts.
Reviewed & verified by the MPN Base engineering desk against source catalog CAT. No. 2203-3/E 2024 on 2026-09-25. Read our editorial & correction policy.