UCP209 bearing: complete specifications & equivalents

The UCP209 is a JIS B 1559 radial bearing sized 45 x 85 x 49.2 mm (bore x OD x width) with 2RS sealing. Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 85 mm d = 45 B = 49.2 mm side section front view
Principal dimensions: bore d 45 mm, outer diameter D 85 mm, width B 49.2 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand NTN
Bore diameter d 45 mm
Outer diameter D 85 mm
Width B 49.2 mm
Seal / shield 2RS
Basic dynamic load rating C 36 kN
Basic static load rating C0 20.4 kN
Fatigue load limit Pu 1.6 kN
Mass 2200 g
Housing height H 54 mm
Housing overall length L 190 mm
Mounting bolt center distance J 146 mm
Mounting hole diameter N 17 mm
Manufacturer designation UCP209
Standard JIS B 1559
Catalog version CAT. No. 2203-3/E 2024
Last verified 2026-09-25

Source: catalog reference (CAT. No. 2203-3/E 2024) · extracted 2026-09-25

Parameters extracted from the official NTN Ball and Roller Bearings catalogue (CAT. No. 2203-3/E 2024); NTN® is a trademark of NTN Corporation, used here for identification only — mpnbase is not an authorized NTN distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at ntnglobal.com.

Dimensions in inches & UCP-series range

Bore d 1.772 in
Outer diameter D 3.346 in
Width B 1.937 in
ISO bore code 09
Radial section height (D−d)/2 20 mm
Smallest bore in UCP-series 12 mm
Largest outer diameter in UCP-series 300 mm
Width range across UCP-series 31–145 mm
Bore position in UCP-series (smallest first) 9 of 25
Bore above smallest UCP-series size 33 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
UCP209 ISO 15 verify
Commonly quoted cross reference; confirm against the target catalog before ordering.
ISO 15 boundary-dimension envelope; seal suffix convention varies by brand (2RS / DDU / LLU / 2RSR) — verify seal design and temperature range. Brand-specific OEM equivalents pending multi-source data.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the UCP209 model number is decoded

NTN ships the UCP209 as a matched assembly — UC209D1 insert swaged into the P209 cast-iron pillow block — so the fitter never has to set bearing-to-housing clearance. The code breaks down as insert family UC, housing form P (pillow block), duty series 2, bore code ending in the 45 mm shaft size; the unit is built from insert UC209D1 and housing P209. For layout work on UCP209: the 45 mm shaft centre sits 54 mm above the sole (H), the footprint is 190 mm long (L), bolt centres are 146 mm (J), and the foot holes suit M14 (17 mm) bolts. The 2-series section is the standard-duty choice — the slimmest, lightest housing at this bore, selected when shaft speed and load are moderate and space is normal. The upright base carries the shaft parallel to and above the mounting surface, which is the arrangement fan, conveyor and transmission drives use whenever a plinth or rail is available. Most general industrial shafting in the 25–50 mm range ends up on exactly this class of unit: designers trade the 2, X and 3 sections against conveyor centres and belt tension rather than against absolute capacity. On machine-tool ancillary drives — chip conveyors, coolant pumps, rotary feeders — this unit is chosen because the spherical fit tolerates a frame welded without precision fixtures. The spherical outer diameter of the insert must be free to pivot in the housing bore during alignment; never pin the insert or weld the housing before the shaft has been turned through several revolutions and the alignment set. Basic ratings of the UC209D1 insert are 36 kN dynamic and 20.4 kN static; the assembled UCP209 weighs about 2.2 kg.

Typical equipment & failure modes

Common applications

  • small crushers and screening feeds
  • textile line-shafting
  • machine-tool chip conveyors
  • long line-shafting where several units must share a straight reference

Known failure patterns

  • grease starvation on long intervals in hot positions, with the ball set running on dried thickener
  • fretting corrosion of the shaft journal under the wide inner ring after years of micro-creep
  • lip-seal failure from grit past the slinger, followed by grease loss and abrasive wear

Selection pitfalls — read before you substitute

  • The standard 2-series insert in UCP209 is the lightest section at 45 mm — do not substitute it into a position that previously ran an X or 3 unit: the 146 mm mounting may match while the load rating does not.
  • As a pillow block, UCP209 needs a prepared horizontal surface at the 54 mm centre height: shim both feet with full-width packs so the 190 mm base seats over its full area.
  • The lip seals and slingers on UCP209 suit ordinary industrial dust; submerged or heavy slurry service needs a different sealed arrangement regardless of the load rating.
  • Never weld a bracket to the P209 housing of UCP209: local heat cracks cast iron and distorts the spherical bore that the insert depends on.
  • With a 45 mm shaft the M14 foundation bolts of UCP209 must be re-checked after run-in — paint crush under the feet is enough to loosen both the feet and the setscrews.

Frequently asked questions

What are the dimensions of an UCP209 mounted bearing?

UCP209 takes a 45 mm shaft (insert UC209D1, 85 mm OD) and has a unit mass of about 2.2 kg. Housing figures: centre height H 54 mm, length L 190 mm, bolt centres J 146 mm, foot holes 17 mm for M14 bolts.

What does the UCP209 designation mean?

UC identifies the wide-inner-ring, setscrew-locking ball bearing insert; P the upright pillow block housing; 2 is the duty series; the last digits encode the 45 mm bore. UCP209 is built from housing P209 plus insert UC209D1 (D1 = greasable).

How is UCP209 locked to the shaft, and how tight should the setscrews be?

The UC209D1 insert uses two collar setscrews on the 45 mm shaft. Tighten them to NTN's torque table for this bore size in sequence — half torque on the first, full on the second, then back to the first — and re-torque after the first 24–48 running hours once the collar has seated.

When should I choose a pillow block like UCP209 instead of a flanged unit?

Choose the UCP209 pillow block when the shaft runs parallel to a horizontal base plate, rail or plinth — the upright housing holds the shaft centre 54 mm above the 190 mm bolt-down base. Choose a UCFL flange when the shaft meets a vertical frame face and the housing bolts flat against it.

How often should I relubricate an UCP209 unit?

There is no single interval for UCP209: the UC209D1 insert is regreased through the D1 fitting while the shaft turns, using an NLGI 2 lithium or lithium-complex grease. Quarterly is typical for normal ambient conveyor duty; shorten to weekly or monthly where temperatures exceed about 70 °C, water is present, or dust is heavy.

Reviewed & verified by the MPN Base engineering desk against source catalog CAT. No. 2203-3/E 2024 on 2026-09-25. Read our editorial & correction policy.