UCP216 bearing: complete specifications & equivalents
The UCP216 is a JIS B 1559 radial bearing sized 80 x 140 x 82.6 mm (bore x OD x width) with 2RS sealing. Verify dimensions against the official catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Brand | NTN |
| Bore diameter d | 80 mm |
| Outer diameter D | 140 mm |
| Width B | 82.6 mm |
| Seal / shield | 2RS |
| Basic dynamic load rating C | 80.5 kN |
| Basic static load rating C0 | 53 kN |
| Fatigue load limit Pu | 3.95 kN |
| Mass | 8700 g |
| Housing height H | 88.9 mm |
| Housing overall length L | 292 mm |
| Mounting bolt center distance J | 232 mm |
| Mounting hole diameter N | 25 mm |
| Manufacturer designation | UCP216 |
| Standard | JIS B 1559 |
| Catalog version | CAT. No. 2203-3/E 2024 |
| Last verified | 2026-09-25 |
Source: catalog reference (CAT. No. 2203-3/E 2024) · extracted 2026-09-25
Parameters extracted from the official NTN Ball and Roller Bearings catalogue (CAT. No. 2203-3/E 2024); NTN® is a trademark of NTN Corporation, used here for identification only — mpnbase is not an authorized NTN distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at ntnglobal.com.
Dimensions in inches & UCP-series range
| Bore d | 3.15 in |
|---|---|
| Outer diameter D | 5.512 in |
| Width B | 3.252 in |
| ISO bore code | 16 |
| Radial section height (D−d)/2 | 30 mm |
| Smallest bore in UCP-series | 12 mm |
| Largest outer diameter in UCP-series | 300 mm |
| Width range across UCP-series | 31–145 mm |
| Bore position in UCP-series (smallest first) | 16 of 25 |
| Bore above smallest UCP-series size | 68 mm |
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| UCP216 | ISO 15 | verify Commonly quoted cross reference; confirm against the target catalog before ordering. | ISO 15 boundary-dimension envelope; seal suffix convention varies by brand (2RS / DDU / LLU / 2RSR) — verify seal design and temperature range. Brand-specific OEM equivalents pending multi-source data. |
Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the UCP216 model number is decoded
The NTN UCP216 unit pairs a UC216D1 sealed ball bearing insert with a one-piece P216 cast-iron pillow block housing, delivered aligned, greased and ready to bolt down. The UCP216 number follows NTN's mounted-unit convention: housing letter P, 2-series section, bore code for 80 mm; P216 and UC216D1 are the separate housing and insert part numbers inside. Shaft size is 80 mm; the cast base stands 88.9 mm to the shaft centre (H), is 292 mm long overall (L), and the two foundation holes on 232 mm centres (J) clear 25 mm M20 bolts. The 2-series section is the standard-duty choice — the slimmest, lightest housing at this bore, selected when shaft speed and load are moderate and space is normal. The upright base carries the shaft parallel to and above the mounting surface, which is the arrangement fan, conveyor and transmission drives use whenever a plinth or rail is available. At 55–90 mm bore the units carry serious conveyor, fan and crusher-feed drives; housing stiffness, foundation condition and bolt torque matter as much as the insert rating. Quarry and aggregate conveyors specify this unit because maintenance crews can unbolt the whole assembly and swap it in minutes; interchangeability across brands at the JIS dimensions is part of the selection logic. Cold-climate users should order the low-temperature grease option or repack before commissioning: the factory fill is a general-purpose NLGI 2 that channels poorly below about −20 °C and starves the ball set on start-up. Basic ratings of the UC216D1 insert are 80.5 kN dynamic and 53 kN static; the assembled UCP216 weighs about 8.7 kg.
Typical equipment & failure modes
Common applications
- process fans and induced-draft drives
- quarry feeder and transfer drives
- sawmill arbors and feed rolls
- cold-store and winter-outdoor service needing low-temperature grease
Known failure patterns
- insert brinelling from hammer mounting or from belt tension applied to a stationary unit
- over-greasing that churns the charge, overheats the bearing and blows the seal lip
- cracked cast ear from mounting on an uneven face and pulling one bolt fully first
Selection pitfalls — read before you substitute
- UCP216 is located on the shaft by setscrews only; for shock reversing drives consider an adapter-lock insert family instead, since setscrew points indent the 80 mm journal over time.
- At 80 mm bore the 292 mm base of UCP216 is a structural member: grout or machine the foundation, because a bedded-on-edges housing concentrates the full belt pull on two cast feet.
- The standard 2-series insert in UCP216 is the lightest section at 80 mm — do not substitute it into a position that previously ran an X or 3 unit: the 232 mm mounting may match while the load rating does not.
- As a pillow block, UCP216 needs a prepared horizontal surface at the 88.9 mm centre height: shim both feet with full-width packs so the 292 mm base seats over its full area.
- At replacement time, measure the 80 mm shaft journal — a worn or deeply indented journal under the setscrews will let a brand-new UCP216 creep identically to the old one.
Frequently asked questions
When should I choose a pillow block like UCP216 instead of a flanged unit?
Choose the UCP216 pillow block when the shaft runs parallel to a horizontal base plate, rail or plinth — the upright housing holds the shaft centre 88.9 mm above the 292 mm bolt-down base. Choose a UCFL flange when the shaft meets a vertical frame face and the housing bolts flat against it.
What loads can the UCP216 unit carry?
The UC216D1 insert is rated at 80.5 kN dynamic and 53 kN basic static (fatigue load limit 3.95 kN). Mounted units are predominantly selected on radial load from belt pull and overhung weight; axial capacity is limited and should be checked separately.
What are the dimensions of an UCP216 mounted bearing?
UCP216 takes a 80 mm shaft (insert UC216D1, 140 mm OD) and has a unit mass of about 8.7 kg. Housing figures: centre height H 88.9 mm, length L 292 mm, bolt centres J 232 mm, foot holes 25 mm for M20 bolts.
What does the UCP216 designation mean?
UC identifies the wide-inner-ring, setscrew-locking ball bearing insert; P the upright pillow block housing; 2 is the duty series; the last digits encode the 80 mm bore. UCP216 is built from housing P216 plus insert UC216D1 (D1 = greasable).
How is UCP216 locked to the shaft, and how tight should the setscrews be?
The UC216D1 insert uses two collar setscrews on the 80 mm shaft. Tighten them to NTN's torque table for this bore size in sequence — half torque on the first, full on the second, then back to the first — and re-torque after the first 24–48 running hours once the collar has seated.
Reviewed & verified by the MPN Base engineering desk against source catalog CAT. No. 2203-3/E 2024 on 2026-09-25. Read our editorial & correction policy.