QJ-314-N2PHAS bearing: complete specifications & equivalents

The QJ-314-N2PHAS is a ISO 15 radial bearing sized 70 x 150 x 35 mm (bore x OD x width). Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 150 mm d = 70 B = 35 mm side section front view
Principal dimensions: bore d 70 mm, outer diameter D 150 mm, width B 35 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand SKF
Bore diameter d 70 mm
Outer diameter D 150 mm
Width B 35 mm
Material GCr15
Seal / shield open
Internal clearance CN
Tolerance class P0
Cage polymer
Basic dynamic load rating C 200 kN
Basic static load rating C0 180 kN
Fatigue load limit Pu 7.35 kN
Limiting speed (mechanical) 8000 rpm
Operating temperature -40 to +120 °C
Mass 3150 g
Manufacturer designation QJ 314 N2PHAS
Standard ISO 15
Catalog version SKF PUB BU/P1 17000/1 EN (Oct 2018)
Last verified 2026-09-27

Source: catalog reference (SKF PUB BU/P1 17000/1 EN (Oct 2018)) · extracted 2026-09-27

Parameters extracted from the official SKF Rolling Bearings catalogue (SKF PUB BU/P1 17000/1 EN (Oct 2018)); SKF® and SKF Explorer® are trademarks of AB SKF, used here for identification only — mpnbase is not an authorized SKF distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at skf.com.

Dimensions in inches & QJ300-series range

Bore d 2.756 in
Outer diameter D 5.906 in
Width B 1.378 in
ISO bore code —
Radial section height (D−d)/2 40 mm
Smallest bore in QJ300-series 17 mm
Largest outer diameter in QJ300-series 400 mm
Width range across QJ300-series 14–78 mm
Bore position in QJ300-series (smallest first) 12 of 27
Bore above smallest QJ300-series size 53 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
7314-BEP SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 119/90 kN) — boundary dimensions match, not a load-rating equivalent.
7314-BECBP SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 127/98 kN) — boundary dimensions match, not a load-rating equivalent.
7314-BECBPH SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 127/98 kN) — boundary dimensions match, not a load-rating equivalent.
7314-BECBY SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 127/98 kN) — boundary dimensions match, not a load-rating equivalent.
7314-BEGAPH SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 127/98 kN) — boundary dimensions match, not a load-rating equivalent.
7314-BECBM SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 127/98 kN) — boundary dimensions match, not a load-rating equivalent.
7314-ACCBM SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
Same 70×150×35 mm envelope, but catalogue C/C0 differ between executions (200/180 kN vs 143/110 kN) — boundary dimensions match, not a load-rating equivalent.
QJ-314-N2MA SKF full
Dimensions and internal design equivalent — standard interchange.
Same 70×150×35 mm envelope with catalogue ratings within 10 %; QJ 314 N2MA is the brass cage, open arrangement, four-point split-inner-ring execution of this size — boundary dimensions interchangeable, execution differs.
QJ-314-MA SKF full
Dimensions and internal design equivalent — standard interchange.
Same 70×150×35 mm envelope with catalogue ratings within 10 %; QJ 314 MA is the brass cage, open arrangement, four-point split-inner-ring execution of this size — boundary dimensions interchangeable, execution differs.
7314 SKF partial
Main dimensions match; tolerances, seals or internal clearance differ.
SKF SKF 7314 BEP shares the 70×150×35 mm angular-contact envelope, but catalogue C/C0 differ (200/180 kN vs 119/90 kN) — envelope match, not a load-rating equivalent.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the QJ-314-N2PHAS model number is decoded

QJ 314 N2PHAS is SKF's 70 mm-bore QJ four-point contact ball bearing of the QJ300 series, 70×150×35 mm, with a two-piece inner ring for bidirectional axial location beside a radial bearing. QJ identifies a four-point contact ball bearing with a two-piece inner ring: the gothic-arch raceways seat each ball at four points, giving axial location in both directions while a paired radial bearing carries the radial load. N2 marks two locating slots, 180° apart, in one outer-ring side face: pins or dogs engage the slots to stop the outer ring turning in its radially-clear housing bore. glass-fibre reinforced PEEK cage, outer-ring-centred with lubrication grooves in the guiding surfaces (suffix PHAS), for very high-speed oil-air or grease lubrication. Envelope 70×150×35 mm (2.756×5.906×1.378 in), 40.0 mm radial section height, C 200 kN, C0 180 kN, Pu 7.35 kN.SKF publishes only the 8,000 r/min limiting speed for this execution, catalogue mass 3150 g. Load balance: C0 180 kN against C 200 kN gives a 0.90 ratio, typical of a four-point thrust-oriented design; Pu 7.35 kN enters the SKF adjusted-life equation rather than the basic rating life. Mass and section check: 3150 g inside the 70×150×35 mm outline leaves a 40.0 mm radial section, and the 180 kN static rating is 0.90× the dynamic rating — plan static safety and minimum load against those numbers rather than against sister executions. Speed-ratio note for this exact unit: no thermal reference speed is listed (seal/grease life governs), so the 8,000 r/min limiting value is the single published ceiling. Locating-slot execution: the two N2 notches are milled into one outer-ring side face exactly 180 degrees apart and engaged by housing dogs or headed pins during assembly; verify dog engagement by hand before the cover goes on, deburr the slot edges after any housing rework, and re-inspect the slot roots for fretting marks at each overhaul because a dog that rides only one slot lets the outer ring walk. The slots identify this order number unmistakably: the plain MA/PHAS execution of the same bore has no notches and must be secured differently.

Typical equipment & failure modes

Common applications

  • paper-machine calender stacks
  • heavy gearbox locating positions
  • screw conveyor and extruder thrust positions

Known failure patterns

  • two-piece inner-ring separation damage if the split ring is pressed or heated unevenly during mounting
  • false brinelling while the shaft stands with pure radial load and no minimum axial load
  • locating-slot root fretting or dog wear when only one N2 notch carries the anti-rotation torque
  • electrical pitting on VFD-driven shafts without grounding protection
  • raceway staining from water in the lubricant during idle periods

Selection pitfalls — read before you substitute

  • Provide a minimum axial load (spring preload is common) so the balls stay correctly seated at speed and light-load conditions; otherwise they skid.
  • Engage the N2 slots with housing dogs at assembly — a radially loose outer ring without positive anti-rotation creeps its seat
  • The PHAS PEEK outer-ring-centred cage with lubrication grooves suits the highest speeds with oil-air lubrication
  • Anti-rotation is built into QJ-314-N2PHAS: check the two N2 slot faces and the engaging housing dogs at every refit, and never rely on cover friction to stop the radially loose outer ring.
  • The PHAS PEEK cage of QJ-314-N2PHAS is outer-ring-centred with lubrication grooves: feed clean oil-air or appropriate grease to the guide land and inspect groove filling at overhaul.
  • Catalogue ratings are SKF PUB BU/P1 17000 figures for QJ 314 N2PHAS as the qj slotted execution; the other order numbers of the QJ 314 size are different products and may carry different ratings — always quote the full designation when purchasing.

Frequently asked questions

What are the dimensions and catalogue data of QJ-314-N2PHAS?

QJ 314 N2PHAS measures 70 mm bore × 150 mm OD × 35 mm width (2.756 × 5.906 × 1.378 in), mass about 3150 g. SKF 17000 ratings: C 200 kN, C0 180 kN, Pu 7.35 kN, SKF publishes only the 8,000 r/min limiting speed for this execution.

What does the N2PHAS suffix mean?

QJ identifies a four-point contact ball bearing with a two-piece inner ring: the gothic-arch raceways seat each ball at four points, giving axial location in both directions while a paired radial bearing carries the radial load. N2 marks two locating slots, 180° apart, in one outer-ring side face: pins or dogs engage the slots to stop the outer ring turning in its radially-clear housing bore. glass-fibre reinforced PEEK cage, outer-ring-centred with lubrication grooves in the guiding surfaces (suffix PHAS), for very high-speed oil-air or grease lubrication.

What are the N2 locating slots for?

The two slots, 180° apart in one outer-ring side face, engage housing dogs or pins to prevent the radially loose outer ring from creeping and fretting its seat. The non-N2 execution relies on other anti-rotation measures.

What minimum axial load does QJ-314-N2PHAS require?

Like angular-contact bearings the QJ needs a minimum axial load to keep the balls seated — spring preload against the outer ring is typical — and the load ratio Fa/Fr ≥ 1,27 keeps contact on one inner-ring raceway and the opposite outer-ring side.